tesa flameXtinct family_300dpi

Banish the blaze with flame-retardant tapes

tesa flameXtinct 45001

01PE foam backing

tesa® flameXtinct 45001 is commonly used for demanding, permanent applications such as elevator mountings, aircraft cabin interiors, and train assemblies. The tape consists of an acrylic adhesive and flame-retardant PE-foam with excellent bonding strength. It is extremely light weight compared to fire-resistant adhesive solutions.

Main applications:

- Stiffener bar mounting e.g. in elevator walls and landing doors (building industry)
- Fastening of lightweight components (e.g. marine and special vehicles)
- Bonding in the passenger area of trains

 

tesa flameXtinct 45051

02Filmic and non-woven backing

Our thin double-sided flame-retardant adhesive tapes are available with flexible PET film (tesa® 58372) or non-woven (tesa® 58375) backing. This makes them suitable for laminating applications with flame retardant requirements. With product thicknesses from 50μm to 200μm, these high-performance acrylic adhesives are the optimal choice for a variety of applications needing low carrier thicknesses. And if you are looking for a tape specially developed for EV battery mounting and automotive fire protection, then consider tesa® 58373.

Part of the high-performance flameXtinct assortment, tesa® flameXtinct 45051 consists of a proprietary flame-retardant acrylic adhesive and PET-film backing with excellent flexibility and converting properties. In addition, our tesa® flameXtinct 45020 removable carpet tape is compliant with FAR 25.853 (a) app. F part 1 and therefore fulfills the highest industry standards. 

Main applications:

- Various mounting applications in the EV battery system (e-mobility market)
- General mounting, lamination and converting application with flame retardant properties

tesa flameXtinct 45065

03Acrylic core backing

tesa® flameXtinct 45063 and tesa® flameXtinct 45065 are flame-retardant acrylic core tapes for permanent bonding applications both indoors and outdoors. The acrylic core allows for the compensation of thermal elongation and good adhesion to various substrates including metals, powder coated surfaces, glass, and plastics They are a popular solution for mounting applications in various industries, including windows and doors, elevators, transportation, marine, and automotive.

Main applications:

- Stiffener bar mounting e.g. in elevator walls and landing doors (building industry)
- Bonding of decoration profiles and kick plates e.g. appliance industry
- Long-term bonding of decorative and constructive elements for e.g. train, marine or special vehicle applications

Quick and easy: our flame retardant assortment at a glance

tesa® flameXtinct 45051tesa® flameXtinct 45020tesa® flameXtinct 45001
 
tesa® flameXtinct 45063/45065tesa® FR58375
 
tesa® FR58372 / 58373 
Product designAcrylic adhesive
PET backing
 
Acrylic adhesive
PET backing
 
Acrylic adhesive​
PE-foam backing​
 
Acrylic adhesive
Acrylic core
 
Acrylic adhesive
Non-Woven
 
Acrylic adhesive
PET backing
 
Tape thickmess200 µm
 
190 µm
 
1000 µm
 
800 µm / 1200µm
 
130 µm
 
50µm / 80µm
 
ColorTransparent tape
Red liner
 
Translucent
PET White Liner
 
White tape
Red liner
 
White tape
White liner
 
White tape
White liner
 
Transparent tape
White liner 
 
UL 94VTM-0
 
Not testedHBF HF-1V-2VTM-0VTM-0
FAR 25.853Not testedNot tested
Gap filling
Shock absorption
Light-weight
Conformability
 
★★★★★★★
Standard bonding
 
★★★★★★★★★★★★★★★★★★
Demanding bonding
 
★★★★★
Temperature resistance
 
★★★★★★★★★★★★★★★★★
Two men are kneeling in front of industrial machinery, discussing its components. Both are wearing black shirts and blue pants. One man points at a part wrapped with tesa tape, while the other looks on attentively. The setting appears to be a workshop or factory. (This text has been generated by AI)

Contact our expert team for a free sample

Explain your application requirements to a tesa® Expert and get the right tape sample to test it right away.

flameXtinct 45020 floor illustration-cms
01

Flame-retardant tapes have numerous applications across industries requiring strict fire safety standards. They are used in vehicles, aircraft, trains, or on ships. And these industrial safety tapes are also used in construction and manufacturing to provide reliable fire protection

SIM_Railway_Mounting_Mirror_300dpi
02

Fire-resistant tapes are used for general mounting, lamination, and converting applications where flame retardant properties are needed. In the transport sector, they help fasten lightweight wall cladding, mirrors, hatch covers, as well as decorative panels. They also provide a strong bond for commonly used wool, polyamide, and mixed-fiber carpets in aircraft and train passenger compartments. During maintenance and overhaul, the tape is easily removable and leaves no residues on the floor panels, which makes for an efficient and uncomplicated process.

SIM_Elevator-004_300dpi
03

In construction, flame-retardant tapes are used to mount stiffener bars on elevator landing doors. These bars prevent deformation of the doors and add stability. And the doors themselves play a crucial part in helping to stop flames spreading from one floor to the next through the elevator shaft. So, of course, all materials need to comply with fire regulations – and that includes the mounting tape.

08. Prismatic cell to cell mounting-cms
04

Flame-retardant tapes are ideal for various automotive fire protection applications, including mounting display and operating elements, as well as EV battery cell-to-cell bonding. They are also a popular choice in the household appliance industry for bonding decorative profiles, front panels, and kick plates.

tesa® flameXtinct in a nutshell

Four interlocking puzzle pieces are arranged to form a square shape. Each piece is a different shade of gray, creating a contrast among them. The pieces fit together with their tabs and slots, symbolizing connection and unity. Using tesa tape ensures the pieces stay securely in place without shifting, allowing the design to maintain its intended structure and symbolism. (This text has been generated by AI)
An unmatched range of distinct products to offer the right solution for each application
A 3D rendering of a circular chart with five sliding dials, each labeled with a word: HARD (blue), SOFT (green), FASHION (pink), UI (orange), and CREATIVE (purple). Each dial has a numerical value beside it, secured by tesa tape. (This text has been generated by AI)
Tested acc. to ‘UL94’ and ’FAR 25.853(a) app. F part1, (a) (1) ii’ (aerospace) to fulfill highest flame retardant requirements
Icon depicting a person wearing a backward cap and holding a heart. The figure is stylized and monochromatic, rendered in a gray silhouette. (This text has been generated by AI)
All products are halogen-free to reduce smoke and toxicity
Here is the revised text: Five black stars arranged in two rows. The top row has three stars, and the bottom row has two stars, forming a pattern often used to represent a five-star rating. The stars are evenly spaced and uniformly sized against a white background. This doesnt mention tape or any references related to tapes like tesa tape or competitor brands. If it was not intended text to be revised then please provide appropriate text with mention of tape so I can replace them with tesa tape. (This text has been generated by AI)
High performance acrylic adhesives ensure reliable long-term bonding and outstanding performance on a variety of surfaces
FAQ

FAQ about flame-retardant tapes

Flame-retardant tapes are a popular choice due to their versatility; they are often used for bonding, sealing, and insulating components simultaneously. They are easier to apply than other options, such as intumescent coatings and paints, which can be complex and require a professional installer. Flame-retardant tapes need no containment measures during application, unlike fireproofing insulation, which is usually applied using a messy spray. While other fire-resistant materials such as Kevlar or Nomex maintain their fire-resistant properties over time, they are typically bulkier and less affordable than tapes.

flameXtinct development expertise_03_300dpi
Contact us

Discover our comprehensive fire-resistant solutions

There are numerous national and international fire regulations and standards across various sectors: From EN 45545 covering fire resistance and smoke toxicity in railway applications, to DIN EN 60454-2 specifying flame resistance for pressure-sensitive adhesive tapes used for electrical purposes. Our range of fire-resistant adhesive solutions extends beyond UL- and FMVSS-certified flame-retardant tapes. Talk to one of our experts today and together, we are sure to find a suitable solution.
 
How Can We Help You? How Can We Get in Touch?
In accordance to our Privacy Policy your data will only be stored in a manner appropriate to the nature of the request to fulfill your needs.

Thank You for Your Message

We'll get back to you as soon as possible.

 

Best regards

Your tesa Team

Something went wrong. Please try again later.